Stress testing of MDI aerosol cans in a controlled water bath
The Stress Test Water Bath is configured to provide operator access to the working area and to stress-test MDI units produced by the filling line. The catalogue describes a single test tank that can accommodate two canister carriers simultaneously.
The water level is maintained at a constant level through a heat tank and overflow arrangement. Canisters are manually loaded into a carrier and lowered into the bath by the provided hoist arrangement.
The catalogue specifies a 180-second water-bath cycle and a temperature range of 50°C ±3°C.
| Model | RE-STWB-56 |
| Dimensions (L × W × H) exterior | L1600 × W540 × H1483 ±50 mm approx. |
| Machine voltage | 200–230 V AC, Single phase, 50 Hz |
| Canister carrier tray size | L320 × W320 × H160 mm approx. |
| Canister carrier tray capacity | 56 MDI aerosol cans per carrier |
| Weight of machine | 115 kg approx. |
| Temperature range | 50°C ±3°C |
| Air pressure | 6–8 bar |
| Electrical requirements | Global Voltage 400–415V, 50/60Hz |
| Contact material | 316 Stainless Steel |
| Water bath cycle time | 180 sec. (3 minute) |
ROPAC India develops machinery and integrated solutions for pharmaceutical and packaging operations, combining engineering practicality with a clean and professional user experience.